ABSTRACT:
Selecting import element, interchangeable with the same kind of products from all the globe (ex. Dynisco, Gefran).
Applying to pressure measuring and controlling in the high temp.liquid medium of Rubber, Plastic, Chemical Fiber Terylence, Poly-ester, Steam and etc.
PARAMETERS:
Capacity Range: 0-1-200MPa
Comprehensive Precision: 0.2%FS, 0.3%FS, 0.5%FS, 1.0%FS
Output Signal: 2mV/V; 2.5mV/V; 3.3mV/V;4~20mA;1~5V;0~5V;0~10V
Use Temp Range: -10~200℃-400℃
Excitation Voltage:
Transducer =10V (6~12)V;Transmitter=24V (9~36)V;Transmitter=15~36V
Eletric Connection: 6 gilded pin / 5 pin
Thread connection:1/2-20UNF
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
EXAMPLE : PT133 - 25M - 01 - C - Q - 6 / 18 - J - L
PT1
33
25
M
01
C
Q
6
18
J
L
33
Models
25
Capacity(Noted by number)
M
Pressure Mearsure( P=Psi, B=Bar, M=MPa )
01
Output Signal (01=2mV/V, 02=2.5mV/V, 03=3.3mV/V ,04=4~20mA, 05=1~5V, 06=0~5V, 07=0~10V )
C
Precision (%FS) (B=0.2, C=0.3, D=0.5, E=1.0 )
Q
Thread Connection (F=M12×1 G=M14×1.5 H=1/2-20 L=M18×1.5M=M22×1.5 N=M28×1.5 P=G3/4 Q=G3/8 )
6
Length of Rigid Stem ( 2 =2.36", 60mm,6=6", 152mm)
18
Length of Flexible Tube(18=18“, 460mm,blank= none)
J
Thermcouple option (J, K, E, PT100 )
L
Electric connection (W=5pin, L=6pin )